Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Guangzhou Sinomedical Limited.  

Agriculture & Food,Apparel & Accessories,Health & Medicine,Security & Protection

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Luna Chen
  • 电话:86-20-84835359
  • 传真:86-20-84835359
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Touch Screen LCD Apply for Medical Patient Monitor
Touch Screen LCD Apply for Medical Patient Monitor
单价 $300.00 / Piece对比
询价 暂无
浏览 143
发货 Chinaguangdongguangzhou
过期 长期有效
更新 2020-05-16 22:05
 
详细信息
Product Name: Touch Screen LCD Apply for Medical Patient Monitor Power Type: Battery Application: Clinical, Household Feature: Reusable 12.1 Inch Monitor: Patient Monitor Monitor: Windows Style, Multi-Channel Display Features: Plug-in Rechargeable Battery, AC/DC Available. Screen and Display: 12.1" TFT Colour Screen ,Folding 90 Degree Intelligent: System Setup Can Be Done Very Easy and Can Be Stor Automatic: Auto Fetal Movement Are Available Trademark: MeCan Origin: China Mainland Product Description 12.1 inch Patient Monitor Touch ScreenFeatures:12.1" color TFT touch screenWindows style, Multi-channel displayBig font interfaceST and arrhythmia analysisDrug dose calculation and titration tableOxyCRG dynamic view displayRespiration monitoring with apnea alarmsAlarm review, arrhythmia reviewPatient info. InputAnti-defibrillation designNIBP over pressure protectionPlug-in rechargeable battery, AC/DC available.Supporting wire or wireless network.Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.Technical SpecificationsSP02Nellcor(TM) OxiMax(TM) is the world leading SpO2 technologyNellcor(TM) OxiMax(TM) delivers excellent performance,even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.ETCO2Collaborate with Respironics, Plug and Play EtCO2 monitoring.CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurateand reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.Multi Mounting SolutionsECGLead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)Lead selection I, II, III, avR, avL, avF, VWave form 2 chLead mode 3 Leads ( R, L, F or RA, LA, LL)Lead selection I, II, III,Wavef orm 1 chGain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, autoHR and Alarm Range Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpmAccuracy ±1% or±1bpm, which is greaterResolution 1 bpmSensitivity > 200 (uVp-p)Differential Input Impedance > 5 MΩCMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dBElectrode offset potential ±300mVLeakage Current < 10 uAbaseline Recovery < 3 S After Defi.ECG Signal Range ±8 m V ( Vp-p )Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 HzCalibration Signal 1 (mVp-p), Accuracy:5%ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mVARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review AvailableRespirationMethod Impedance between R-F(RA-LL)Differential Input Impedance > 2.5 MΩMeasuring Impedance Range 0.3~3 Ωbase line Impedance Range 200~4 KΩBandwidth 0.1~2.5HzResp. Rate Measuring and Alarm Range Adult 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 BrpmApnea Alarm 10 ~ 40 SNIBPMethod OscillometricMode Manual, Auto, STAT Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)Measuring Period in STAT Mode 5 MinPulse Rate Range 40 ~ 240 bpmAlarm Type SYS, DIA, MEANMeasuring and alarm range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHgResolution 1mmHgAccuracy Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHgOverpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHgSpO2Measuring Range 0 ~ 100 %Alarm Range 0 ~ 100 %Resolution 1 %Accuracy 70% ~ 100% 2 % 0% ~ 69% unspecifiedActualization intervalabout 1 Sec.Alarm Delay 10 Sec.Pulse Rate Measuring and Alarm Range 20~300 bpm Resolution 1bpm Accuracy ±3bpm TEMPChanne 2Measuring and Alarm Range 0 ~ 50 ºCResolution 0.1 ºCAccuracy ±0.2 ºCActualization intervalabout 1 Sec.Average Time Constant < 10 Sec.IBPLabel ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHgPress Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000ΩResolution 1 mmHgAccuracy ±2% or 1mmHg which is greaterActualization interval about 1 secretary Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, TemperatureOptional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder